327
3. TERMOPID FUNCTIONING AND PROGRAMMING
ThermoPID double temperature
Through one of the TermoPID models mounted, it is possible to adjust the
temperature of the machine boilers.
To set the temperature, proceed as follows.
Set-point temperature programming
To access the set point temperature adjustment programming, proceed as
follows:
• With the termopid enabled (on), press the
▼
and
▲
keys simultaneously.
• When the display shows “t1” press the
▼
key to scan the set points “t1 or
t2”.
• When the display shows the required set point “t1 or t2” press
▲.
• The display will show the set point temperature entered; it is then possible to
modify the value of the temperature required with the
▼
and
▲
keys.
• 3 seconds after the pressing of the last key, the data is stored and the display
will show the current temperature.