Appendix A - Technical Data
Environmental Conditions
QMOD dryers are designed for operation
under the following conditions:
Indoor use
Altitude up to 2000 m / 16,565 ft.
Ambient temperature 5°C / 41°F to
40°C / 104°F
Maximum RH 80% for temperatures up
to 31°C / 88°F, decreasing linearly to
50% RH at 40°C / 104°F
•
•
•
•
Main supply voltage fluctuations not to
exceed +/- 10% of nominal
Transient over voltage IEC664 Class II
Pollution degree 2, IEC 664
NOTICE!
For operation extended from the
above conditions, please contact
Quincy Compressor.
•
•
•
Specifications
Dryer Sizing Table
Dryer moDel
PiPe
Size
(in)
i
nlet Flow rAte
Dryer
conFigurAtion
DimenSionS (mm) DimenSionS (in)
n
m
3
/H ScFm l/min A B c A B c
qmod00008 3/8 14 8 227 simplex 565 281 92 21.7 11.06 3.6
qmod00010
3/8 17 10 283 simplex 635 281 92 25.7 11.06 3.6
qmod00015
3/8 26 15 425 simplex 815 281 92 29.6 11.06 3.6
qmod00025
3/8 43 25 708 simplex 1205 281 92 33.5 11.06 3.6
qmod00035
3/8 60 35 991 simplex 1598 281 92 41.4 11.06 3.6
NOTICE!
The temperature and pressure correction factors in the Specification Tables should
be applied to the flow rates in the Dryer Sizing Table to suit the application and
ensure dryer performance. All flow rates are based on 7.0 barg (100 psig) and 35°C
(95°F) at the dryer inlet.
28 Quincy Compressor-QMOD