80 Quincy Compressor
• Preventive maintenance schedule
• Service kits
• Disposal of used material
Preventive maintenance schedule
Warning
CAUTION!
Before carrying out any maintenance, repair work or adjustments, proceed as follows:
• Stop the compressor.
• Switch off the voltage and open the isolating switch.
• Press the emergency stop button (S3).
• Close the air outlet valve.
• Depressurize the compressor by opening the manual drain valve(s).
The operator must apply all relevant Safety precautions during maintenance or repair.
Warranty - Product Liability
Useonlyauthorizedparts.Anydamageormalfunctioncausedbytheuseof
unauthorizedpartsisnotcoveredbyWarrantyorProductLiability.
General
Whenservicing,replaceallremovedgaskets,O-ringsandwashers.
Intervals
ThelocalCustomerCentremayoverrulethespeciedmaintenanceschedule,especially
the service intervals, depending on the environmental and operating conditions of the
compressor.
NOTICE!
The longer interval checks must always include the shorter interval checks.
Preventive maintenance schedule
AnumberofserviceoperationsaregroupedinplanscalledServiceplansI,A,BorD.
Seethetablebelow.Amessagewillappearonthecontrollerdisplaywhenreaching
theinterval,indicatingwhichServiceplansaretobecarriedout.Afterservicing,the
regulatoristobereset.Fordetailedinformation,consultsectionServicemenu.
Period
(note 1)
Running
hours
(note 1)
Service
Plan
Operation
Daily - -
•Checkreadingsondisplay.
•Checkifcondensateisdischargedduringoperation.
•Draincondensatemanually(whenapplicable).
•Oncompressorswithintegrateddryer:checkthedew
point.
Every3
months
(note 2)
500 - •Checkthepressuredropoverthe(optional)lters.
•Inspecttheairinletlters:checkforcleannessanddam-
age. Replace a dirty or damaged filter with a new one.
•Checkthecoolers.Cleanbyairjetifnecessary.