Section VIII - Problem solving
Quincy Compressor 89
NOTICE!
Before carrying out any maintenance or repair, perform following steps:
• Stop the compressor and switch off the voltage.
• Open and lock the isolating switch to prevent an accidental start.
• Isolate the compressor by closing the outlet valve.
• Depressurize the system by opening the drain valve(s).
Compressor
Condition Fault Remedy
Thecompressor
does not start.
Pressuretoohigh.
Compressor will start again
when the pressure drops to the
starting pressure.
Loose connection.
Checkallelectricalconnections.
Safety valve blows.
Pressuretoohigh Checksettingsandcorrect.
Safety valve opens too soon. Replace valve.
Compressor
capacity or pressure
below normal.
Airconsumptionexceeds
capacity of compressor.
Checkequipmentconnected.
Chokedairinletlter.
Removeandchecklter.Replace
if necessary.
Safetyvalveleaking. Replace valve.
Compressor element out of
order.
Consult your supplier.
Compressor
module overheating
or compressor
shutdown on high
air temperature.
Insufcientcompressor
cooling.
Improveventilationof
compressor room. Clean
compressor element fins
and fan, see Cleaning the
compressor element.
Cooling fan out of order.
Checkandcorrect.
Condensate trap
continuously
discharging air an
water
Automaticdrainoutoforder
Havethedrainchecked.Replace
as necessary
Refrigerant dryer
Forcompressorswithabuilt-inrefrigerantdryeralso: