RadioLink Electronic Limited
www.radiolink.com
14
3.2.3 END POINT ADJUSTMENT (EPA)
This function is used to set travel range of the servo connected to the channel.
When setting the model or after the first flight, if you feel that the movement of the model is still
relatively small when you move the joystick to the maximum position. You can increase the travel range
percentage of the corresponding channel of the servo (the maximum can be adjusted to 120, The default is
96).
The interface of parameter setup APP on phone.
The interface of parameter setup software on computer.
EPA-L and EPA-R respectively represent the travel range on two sides of the neutral point. You can
choose the side you want to modify to adjust travel range percentage.