Raisecom
Gazelle S1020i-GL (A) User Manual
2 Hardware structure
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
23
Figure 2-13 Alarm output interface 1
Alarm output interface 2
The alarm output interface on the Gazelle S1020i-2GF-4GE-GL and Gazelle S1020i-4GF-
8GE-GL is in form of 3-pin Phoenix connector with spaces of 7.62 mm, as shown in Figure 2-
14.
Figure 2-14 Alarm output interface 2
Alarm status
When an alarm is generated, PIN 1 and PIN 2 are connected and thus the ALM LED is
on.
When no alarm is generated, PIN 2 and PIN 3 are connected and thus the ALM LED is
off.
Table 2-13 lists parameters of the alarm output interface.
Table 2-13 Parameters of the alarm output interface
Parameter
Description
Connector type
7.62 mm × 3-pin phoenix terminal
Electrical feature
Connected/Disconnected
Maximum switching voltage
250 VAC/125 VDC
Maximum switching current
3 A (250 VAC/30 VDC)
Maximum switching capability
90 W