Table 2-15 Configuring triggering condition
Enter global configuration mode.
Raisecom(config
)#alarm
outside-alarm
num
{ high |
low }
Configure the triggering condition of an external alarm
to high level or low level.
Num: being 1 or 2, DI ID
High: configure the triggering condition to high level.
Low: configure the triggering condition to low level.
By default, each external alarm is triggered by
high level.
Table 2-16 lists parameters of the DI interface.
Table 2-16 Parameters of the DI interface
5.08 mm × 5-pin Phoenix connector
2.4 LEDs
Table 2-17 lists LEDs on the Gazelle S1020i-GL, which are located at the line side on the
front panel. Lights are guided to the front panel through light pipes.
Table 2-17 LEDs
Green: the power supply is normal.
Off: the power supply is abnormal or off.
Green: the system is being started or
working improperly.
Blinking green: the system is working
properly.
Off: the system is being started or working
improperly.