2 Hardware structure
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
25
Table 2-15 Configuring triggering condition
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config
)#alarm
outside-alarm
num
{ high |
low }
Configure the triggering condition of an external alarm
to high level or low level.
Num: being 1 or 2, DI ID
High: configure the triggering condition to high level.
Low: configure the triggering condition to low level.
By default, each external alarm is triggered by
high level.
Table 2-16 lists parameters of the DI interface.
Table 2-16 Parameters of the DI interface
Parameter
Description
Connector type
5.08 mm × 5-pin Phoenix connector
Input voltage range
-30 to +30 VDC
High level
1330 VDC
Low level
-30 to +1 VDC
Maximum input current
8 mA
2.4 LEDs
Table 2-17 lists LEDs on the Gazelle S1020i-GL, which are located at the line side on the
front panel. Lights are guided to the front panel through light pipes.
Table 2-17 LEDs
LED
Print
Status
Description
DC power status
LED
PWR1
PWR2
Green
Green: the power supply is normal.
Off: the power supply is abnormal or off.
System status
LED
SYS
Green
Green: the system is being started or
working improperly.
Blinking green: the system is working
properly.
Off: the system is being started or working
improperly.