Operating Manual 1302.6163.12 - 03 6.23
R&S ESU Remote Control – Description of Commands
CALCulate Subsystem
Switching on and evaluating the line in screen A (example for analyzer mode):
1. Switching on the line in screen A: CALC1:LIM5:UPP:STAT ON
2. Switching on the limit check in screen A: CALC1:LIM5:STAT ON
3. Starting a new measurement with synchronization: INIT;*WAI
4. Querying the limit check result: CALC1:LIM5:FAIL?
Switching on and evaluating the line in screen B is performed in the same way by using CALC2 instead of
CALC1.
CALCulate<1|2>:LIMit<1...8>:ACTive?
This commands queries the names of all active limit lines. The numeric suffixes at CALCulate<1|2>
and LIMit<1...8> are ignored.
Return value: The return values are sorted in alphabetic order. If no limit line is active, an empty
string is returned.
Example: "CALC:LIM:ACT?"
Characteristics: *RST value: --
SCPI: device-specific
Mode: R, A
This command is a query only and therefore has no *RST value.
CALCulate<1|2>:LIMit<1...8>:CATalog?
This command queries all the names of the limit lines saved on the hard disc.
Up to 8 limit lines can be defined at the same time. The numeric suffixes <1|2> of CALCulate indicate
the measurement window.
Return value: The syntax of the return values is:
<sum of file length of all following files>,<free spaces on hard disc>,<1st file
name>,<1st file length>, <2nd file name>,<2 nd file length>,....,<n th file
name>,<nth file length>
Example: "CALC:LIM:CAT?"
Characteristics: *RST value: -
SCPI: device-specific
Mode: R, A
This command is a query only and therefore has no *RST value.
CALCulate<1|2>:LIMit<1...8>:TRACe 1 to 3
This command assigns a limit line to a trace.
Up to 8 limit lines can be defined at the same time. The numeric suffixes <1|2> of CALCulate indicate
the measurement window.
Example: "CALC:LIM2:TRAC 3"
'Assigns limit line 2 to trace 3 in screen A.
"CALC2:LIM2:TRAC 1"
'Assigns limit line 2 to trace 1 in screen B at the same time.