Operating Manual 1302.6163.12 - 03 6.43
R&S ESU Remote Control – Description of Commands
CALCulate Subsystem
time (span = 0)
level (APD/CCDF measurement)
If marker 2, 3 or 4 is selected and used as delta marker, it is switched to marker mode.
The measurement windows are selected via CALCulate1 (screen A) or 2 (screen B).
Example: "CALC1:MARK2:X 10.7MHz"
'Positions marker 2 in screen A to frequency 10.7 MHz.
Characteristics: *RST value: -
SCPI: device-specific
Mode: R, A
CALCulate<1|2>:MARKer<1...4>:X:SLIMits[:STATe] ON | OFF
This command switches between a limited (ON) and unlimited (OFF) search range in the selected
measurement window. The function is independent of the selection of a marker, i.e. the numeric suffix
MARKer<1...4> is irrelevant.
If the time domain power measurement is active, this command limits the evaluation range on the
trace.
Example: "CALC:MARK:X:SLIM ON"
'Switches on search limitation in screen A.
Characteristics: *RST value: OFF
SCPI: device-specific
Mode: R, A
CALCulate<1|2>:MARKer<1...4>:X:SLIMits:LEFT 0 to MAX (frequency | sweep time)
This command sets the left limit of the search range for markers and delta markers in the selected
measurement window. Depending on the x-axis domain, the indicated value defines:
frequency (span > 0)
time (span = 0)
The function is independent of the selection of a marker, i.e. the numeric suffix in MARKer<1...4> is
irrelevant.
If the time domain power measurement is active, this command limits the evaluation range to the trace.
Example: "CALC:MARK:X:SLIM ON"
'Switches the search limit function on for screen A.
"CALC:MARK:X:SLIM:LEFT 10MHz"
'Sets the left limit of the search range in screen A to 10 MHz.
Characteristics: *RST value: - (is set to the left diagram border on switching on search limits)
SCPI: device-specific
Mode: R, A
The function is only available if the search limit for marker and delta marker is
switched on (CALC:MARK:X:SLIM ON).