R&S ESU Remote Control – Description of Commands
CALCulate Subsystem
6.68 Operating Manual 1302.6163.12 - 03
Example of channel/adjacent channel power measurement:
If the channel power only is to be measured, all commands relating to adjacent/alternate channel
bandwidth and channel spacings are omitted. The number of adjacent/alternate channels is set to 0
with SENS2:POW:ACH:ACP 0.
Example of occupied bandwidth measurement:
Characteristics: *RST value: -
SCPI: device-specific
Mode: A-F
"SENS2:POW:ACH:ACP 3" 'Sets the number of adjacent/alternate channels in
screen B to 3.
"SENS2:POW:ACH:BAND 30KHZ" 'Sets the bandwidth of the transmission channel to
30 kHz.
"SENS2:POW:ACH:BAND:ACH 40KHZ" 'Sets the bandwidth of each adjacent channel to 40 kHz.
"SENS2:POW:ACH:BAND:ALT1 50KHZ" 'Sets the bandwidth of each alternate channel to 50 kHz.
"SENS2:POW:ACH:BAND:ALT2 60KHZ" 'Sets the bandwidth of alternate channel 2 to 60 kHz.
"SENS2:POW:ACH:SPAC 30KHZ" 'Sets the spacing between the transmission channel and
the adjacent channel to 30 kHz, the spacing between the
transmission channel and alternate channel 1 to 60 kHz,
and the spacing between the transmission channel and
alternate channel 2 to 90 kHz.
"SENS2:POW:ACH:SPAC:ALT1 100KHZ" 'Sets the spacing between the transmission channel and
alternate channel 1 to 100 kHz, and the spacing between
the transmission channel and alternate channel 2 to
150 kHz.
"SENS2:POW:ACH:SPAC:ALT2 140KHZ" 'Sets the spacing between the transmission channel and
alternate channel 2 to 140 kHz.
"SENS2:POW:ACH:MODE ABS" 'Switches on absolute power measurement.
"CALC2:MARK:FUNC:POW:SEL ACP" 'Switches on the adjacent channel power measurement in
screen B.
"INIT:CONT OFF" 'Switches over to single-sweep mode.
"INIT;*WAI" 'Starts a sweep and waits for the end of the sweep.
"CALC2:MARK:FUNC:POW:RES? ACP" 'Queries the result of adjacent channel power measure-
ment in screen B.
"SENS2:POW:ACH:REF:AUTO ONCE" 'Defines the measured channel power as the reference
value for relative power measurements.
"SENS2:POW:BAND 90PCT" 'Defines 90% as the percentage of the power to be con-
tained in the bandwidth range to be measured.
"INIT:CONT OFF" 'Switches over to single-sweep mode.
"INIT;*WAI" 'Starts a sweep and waits for the end of the sweep.
"CALC2:MARK:FUNC:POW:RES? OBW" 'Queries the occupied bandwidth measured in screen B.