R&S ESU Remote Control – Description of Commands
INSTrument Subsystem
6.136 Operating Manual 1302.6163.12 - 03
INSTrument:COUPle:CENTer ALL | NONE
This command couples the center frequency and receive frequency settings for the analyzer and
receiver modes with one another.
Example: "INST:COUP:CENT ALL"
Characteristics: *RST value:ALL
SCPI:device-specific
Mode: R, A
INSTrument:COUPle:DEModulation ALL | NONE
This command couples the settings of the audio demodulator for the analyzer and receiver modes with
one another.
Example: "INST:COUP:DEM ALL"
Characteristics: *RST value:NONE
SCPI:device-specific
Mode: R, A
INSTrument:COUPle:GAIN ALL | NONE
This command couples gain settings for the analyzer and receiver modes with one another.
Example: "INST:COUP:GAIN ALL"
Characteristics: *RST value:ALL
SCPI:device-specific
Mode: R, A
INSTrument:COUPle:MARKer ALL | NONE
This command couples the frequency of the marker in spectrum analyzer mode to the receive
frequency in receiver mode
Example: “INST:COUP:MARK ALL”
Characteristics: *RST value: NONE
SCPI: device-specific
Mode: R, A
INSTrument:COUPle:PRESelector ALL | NONE
This command couples the activation of the preselector for the analyzer and receiver modes with one
another.
In receiver mode, the preselector cannot be deactivated. In normal operation, this means that the
preselector is always automatically activated when a change to the analyzer mode occurs and
coupling has been activated.
Example: "INST:COUP:PRES ALL"
Characteristics: *RST value:ALL
SCPI:device-specific
Mode: R, A