Operating Manual 1302.6163.12 - 03 6.175
R&S ESU Remote Control – Description of Commands
SENSe Subsystem
Characteristics: *RST value:-20 dBm
SCPI: device-specific
Mode: A
[SENSe<1|2>:]ESPectrum:RANGe<1…20>:SWEep:TIME <numeric_value>
This command defines the sweep duration of a range in the Spectrum Emission Mask measurement.
The numeric suffixes <1...20> specify the range.
Example: "ESP:RANG2:SWE:TIME 1MS"
'sets the sweep time in range 2 to 1 ms
Characteristics: *RST value:depends on range
SCPI: device-specific
Mode: A
[SENSe<1|2>:]ESPectrum:RANGe<1…20>:SWEep:TIME:AUTO ON | OFF
This command controls the automatic coupling of the sweep duration on the frequency span and the
bandwidth settings in a Spectrum Emission Mask measurement range.
The numeric suffixes <1...20> specify the range. The numeric suffix at SENSe<1|2> is irrelevant.
Example: "ESP:RANG2:SWE:TIME:AUTO ON"
'activates the coupling of frequency range and bandwidths in range 2
Characteristics: *RST value: ON
SCPI: device-specific
Mode: A
[SENSe<1|2>:]ESPectrum:RANGe<1…20>:TRANsducer <string>
This command sets the transducer factor for a range in the Spectrum Emission Mask measurement.
The numeric suffixes <1...20> specify the range. The numeric suffix at SENSe<1|2> is irrelevant.
Example: "ESP:RANG2:TRAN 'fac_1’"
'sets the transducer factor fac_1 in range 2
Characteristics: *RST value:-
SCPI: device-specific
Mode: A
[SENSe<1|2>:]ESPectrum:RRANge?
This command returns the numer of the reference range of the Spectrum Emission Mask
measurement.
The numeric suffixes <1...20> specify the range. The numeric suffix at SENSe<1|2> is irrelevant.
Example: "ESP:RRAN?"
Characteristics: *RST value:-