Operating Manual 1302.6163.12 - 03 6.179
R&S ESU Remote Control – Description of Commands
SENSe Subsystem
[SENSe<1|2>:]FMEasurement:TIME <numeric_value>
This command defines the measurement time in which the values indicated in the peak list (final
measurement values) are re-checked.
Example: ":FME:TIME 0.01"
Characteristics: *RST value: 1 s
SCPI: device-specific
Mode: R