Page #114 background imageLoading...
Page #114 background image
R&S OSP Instrument Functions
Operating Manual 1505.3896.12 - 14 99
Figure 5-35: Block diagram Module R&S OSP-B126
When the module OSP-B125/126 is configured within the OSP120, a manual
operation of the module can be performed via the OSP Panel. See chapter 3.3 for
details.
For remote control operation see chapters 6 and 7.
The OSP-B125/126 is a three-slot module. Within one OSP120 only one module of
this type can be installed.
If more than one OSP-B125/126 are required, the extension unit OSP150 must be
used. For further information on the extension unit OSP150 see chapter 8.2.
5.2.11 Module R&S OSP-B114 for EMS application
The module R&S OSP-B114 is intended for applications in small or medium systems
for Electromagnetic Susceptibility (EMS). The module fulfills the following tasks:
Switching of the output of two power amplifiers to one or two transmit antennas
(or other kind of transducers).
Providing the circuitry for an interlock loop with the following functions:
monitoring a interlock loop and read/display the actual status
power down external amplifiers depending on interlock status
disconnect the signal generator from power amplifier (if they cannot be
powered down) depending on interlock status
Four output lines. Can be used to control the polarization of the transmitting
antennas
Four input lines