Page #143 background image
R&S OSP Instrument Functions
Operating Manual 1505.3896.12 - 14 128
The numbers at each relay label (K11 to K16) show the cycles, the relays already have
been switched to NO and NC position, respectively.
Selecting this button will read the actual state of the switch cycle counter.
Pressing this button will exit the dialog.
R&S OSP Switch Cycle Counter
Note that the OSP switch cycle counter state is stored on the corresponding switch
module on-board memory. To reduce the write operations for the on-board memory,
the cycles are stored on the following events:
each 60 minutes
every 1000 cycles
on each “Fetch Counters” command (only if counter state has changed)