14 | Automatic cleaning - iCareSystem
Original user’s manual 55 / 84
n
Do not clean the externally attached core temperature probes
using automatic cleaning.
n
Before preheating the unit for cooking, remove all cleaning
products and cleaning product residues.
How to respond if you come into contact with cleaning chemicals:
n
If you touch cleaning agents when not wearing gloves or your
skin otherwise comes into contact with Active Green cleaner
tabs, rinse your skin with running water for 10 minutes.
n
If you get cleaning chemicals into your eyes, rinse your eyes
with running water for 15 minutes. Remove your contact
lenses, if applicable.
n
If you swallow cleaning chemicals, rinse your mouth out with
water and drink two glasses of water immediately. Do not
induce vomiting.
n
Call the poison control hotline or a doctor immediately.
14.2 Cleaning modes
The light, medium and fast cleaning programs can be used in two different
cleaning modes:
Eco mode
If you select this cleaning mode, cleaning programs [}55] will clean the unit
using less water and cleaning chemicals, but cleaning will take longer than it does
in Normal mode.
Normal mode
If you select this cleaning mode, cleaning programs [}55] will use more cleaning
chemicals and water to clean the unit, but they will be shorter than in Eco mode.
14.3 Cleaning programs
The following cleaning programs are available to you:
Program Mode Description Care product
light Eco /
Normal
Suitable for removing
minor food residue and
limescale accumulated
n
Active Green
cleaner tabs