14.5.1 Balancing mode
The machine has the ability to perform the wheel bal-
ancing (weights fitting) in 3 different ways:
- using the distance-diameter caliper arm with weights
fitting grippers;
- using the laser at “6 o'clock”;
- weights fitting at “6 o'clock” (without the use of lasers).
• Weights fitting with distance-diameter caliper
arm.
1. Place the adhesive weight on the arm grippers.
Fit the adhesive weight in the
pliers of the gauge rod
2. Pull out the gauge until the arrows (Fig. 46 ref._6)
both turn green.
3. Rotate the gauge arm until the weight touches
the rim.
Fit weight on the position where
pliers touches the wheel
4. Bring the distance-diameter caliper arm into rest-
ing position.
5. Press the button to change the weight fit-
ting side.
6. Proceed in the same way as described in points
1-2-3.
IF THE GUARD AND REPOSITION-
ING FUNCTION ARE DISABLED,
ON BUTTON 7 YOU WILL SEE
THE ICON THAT WILL AL-
LOW THE WHEEL SPIN WITHOUT
RETURNING TO THE PREVIOUS
PAGE. THE POSITIONING OF THE
WHEEL FOR THE APPLICATION
OF THE WEIGHTS MUST BE DONE
MANUALLY.