EXAMPLE: Assume DISTANCE reads 5000 [980].
Corrected SPEED CAL =
Old SPEED CAL x 5280
DISTANCE
ENGLISH UNITS: METRIC UNITS:
= 598 x 5280 = 631.48 = [152] x [1000] = [155]
5000 [980]
The number to enter for SPEED CAL is 631 [155].
5) Enter the number calculated for SPEED CAL.
6) Recheck the new SPEED CAL derived in Step 5 by repeating Steps 2 thru 5.
3. CALCULATING "METER CAL"
The Flow Meter calibration number is stamped on the tag attached to each Flow Meter. Write down