27
DECIMAL PLACE LOCATIONS
11. DECIMAL SHIFT
The DECIMAL SHIFT feature is used to increase system accuracy at low application rates. Shifting
of the decimal point is done during the entry of METER CAL. After entering METER CAL mode,
depress the decimal shift , enter the meter calibration constant number, and depress .
The sequence to unshift the decimals while in METER CAL is to enter the meter calibration constant
number and depress . The following table illustrates how shifting the decimal point can
increase system accuracy.
US METRIC TURF
UNSHIFT SHIFT UNSHIFT SHIFT UNSHIFT SHIFT
RATE DISPLAY 000.0 00.00 0000 000.0 00.00 00.00
RATE 1 CAL 000.0 00.00 0000 000.0 00.00 00.00
RATE 2 CAL 000.0 00.00 0000 000.0 00.00 00.00
TANK VOLUME 0000 000.0 0000 000.0 000.0 000.0
TOTAL AREA 000.0 000.0 000.0 000.0 0000 0000
TOTAL VOLUME 0000 000.0 0000 000.0 000.0 000.0
FIELD AREA 000.0 000.0 000.0 000.0 0000 0000
FIELD VOLUME 0000 000.0 0000 000.0 000.0 000.0
VOL/MINUTE 0000 000.0 0000 000.0 000.0 000.0
AREA/HOUR 000.0 000.0 000.0 000.0 0000 0000
RATE +/- 000.0 00.00 0000 000.0 00.00 00.00
LOW TANK LEVEL 0000 000.0 0000 000.0 000.0 000.0
LOW VOL/MIN 0000 000.0 0000 000.0 000.0 000.0
When entering RATE 1 CAL and RATE 2 CAL, remember that 2 GPA [20 lit/ha] is entered as 2.0 [20.0]
when unshifted and 2.00 [20.00] when shifted.