26
22) DATA-LOCK
Sequence to activate DATA-LOCK CODE (feature prohibits the entry of data without first entering
the DATA-LOCK CODE).
a) Display will show
PRESS ENTER FOR DATA-LOCK
.
Press
.
b) Display will show
NEW CODE E
.
c) Enter 4-digit code within 15 seconds.
(i.e. 1058, press and ).
Sequence to change DATA-LOCK CODE.
a) Press until display shows
PRESS ENTER FOR DATA-LOCK
.
Press .
b) Display will show
OLD CODE E
.
c) Enter 4-digit old code within 15 seconds and press . Display will show
NEW CODE E
.
d) Enter 4-digit new code within 15 seconds or 0 to clear data-lock.
To enter mode sequence with activated DATA-LOCK CODE.
a) Depress the key in which data is to be entered. Depress . Code message will
appear.
b) Enter the DATA-LOCK CODE. If code is correct, E will appear. Now enter data normally.
The data lock may be cleared by entering 0 or by resetting the console. To reset the console,
place power ON/OFF switch to OFF, depress and hold while placing the power
ON/OFF switch to ON.
NOTE: The DATA-LOCK feature prohibits the entry of data without first entering
the DATA-LOCK CODE.
20) MAXIMUM SYSTEM PRESSURE 60
a) Display will show
MAXIMUM SYSTEM PRESSURE 60.
b) Press . Enter the maximum pressure for the system (i.e. 65 PSI). Press
, depress again.
c) Momentarily depress to advance to DATA LOCK (console skips TIER A ONLY
when in automatic mode).
21) TIER A ONLY
a) Display will show TIER A ONLY.
b) Momentarily depressing scrolls through the different manual tier control options.
The options include TIER A ONLY (default), TIER B ONLY, TIERS A AND B, TIER C
ONLY, TIERS B AND C, and ALL 3 TIERS.
c) Momentarily depress to advance to DATA LOCK.