8
Machine Panel and Configurations: 73
MACHINE PANEL AND CONFIGURATIONS
SECTION SETTINGS
To set up or modify section settings on an implement:
1. Touch the Edit icon in the Machine Panel to view the machine devices.
2. Touch the Machine Profile (for self-propelled implements) button or the Implement Profile (for pull-type
implements) button to access the profile settings.
3. Select the Equipment tab.
4. Touch the:
Add button to create a new section group and use the on-screen keyboard to enter a group name
or description for the new group.
Edit button to modify group and section settings for an existing section group.
NOTE: If no section groups are configured, the Add button will be displayed in the first group.
5. Touch the General Information tab.
6. Select the Name field and enter the desired name or description of the section group.
7. Touch the Type drop down field and select the type of sections in the group.
8. Enter any applicable information to be shown with the completed job or field report in the lower portion of the
General Information tab.
9. Touch the Measurements tab.
10. Configure the overall offset of the implement (e.g. spray boom, spread pattern, knives or shanks, etc.) from the
center of the machine or implement pivot point as necessary.
a. Select the left/right offset direction and select the offset distance field and use the on-screen keypad to
enter the distance from the center of the implement pivot point to the center of the section group. Refer
to the Equipment Setup - Measurements Tab section on page 84 for additional information on measuring
the implement offsets.
b. Select the aft offset distance field and use the on-screen keypad to enter the distance from the center of
the implement pivot point to the center of the section group. Refer to the Equipment Setup -
Measurements Tab section on page 84 for additional information on measuring implement offsets.
11. Touch the Sections tab.
12. Touch the Number of Sections field and use the on-screen keypad to enter the number of sections in the
group. ROS will update the sections display with the appropriate number of sections.
13. Touch a section indicator to display section settings.
14. Touch the section label field and use the on-screen keyboard to enter the desired label (up to three characters)
for the section.
Edit Machine
Profile
Equipment
Implement
Profile
or
Add
Edit
MeasurementsGeneral
Information
Sections

Table of Contents