Figure 12 Control signal connectors
4.4.1 Safety XP2 24 PinInterface
The 24-pin hard wire interface, with remote control system power-on, remote main power power-on,
and active and passive output of some lasers. Detailed interface definitions are shown below:
Table 5 Safety XP2 24 pin interface definition
No.
Type
Description
1
MOD+
Laser emission control, voltage input
Fiber Laser ON430 V
Fiber Laser OFF-32 V;
Maximum modulation frequency5 kHz.
2
MOD-
3
OUT (FET S pole)
Laser emission indicator, MOSFET D pole, S pole output
electric current 1AVds30V
Passive Signal
4
OUT (FET D pole)
5
OUT
Laser emission warning light negativeelectric current100mA
6
OUT
The main power supply is energized to the negative of the warning lampelectric current
100 mA
7
OUT (24V)
The laser emission and the main power supply are energized to the positive pole of the
warning lightelectric current400mA
8
IN
During REM mode, the remote main control board is powered on, 24V active contact
input, and external voltage or grounding is not allowed When pin 8 and 9 are closed,
the main control board will be powered on.
9
IN
10
24V OUT
The laser emission and the main power supply are energized to the positive pole of the
warning lightelectric current400mA.
11
OUT
Front panel emergency stop output 1, relay contact output, passive contact
electric current100mAvoltage30V
14
OUT
XP1: Hardwire
XP2: Safety
XP4: Analogue
XP3: RS-232
XP2: Ethernet (RF-45)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raycus RFL-3000/3000-ABP and is the answer not in the manual?

Raycus RFL-3000/3000-ABP Specifications

General IconGeneral
BrandRaycus
ModelRFL-3000/3000-ABP
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals