Figure 12 Control signal connectors
4.4.1 Safety XP2 24 PinInterface
The 24-pin hard wire interface, with remote control system power-on, remote main power power-on,
and active and passive output of some lasers. Detailed interface definitions are shown below:
Table 5 Safety XP2 24 pin interface definition
Laser emission control, voltage input;
Fiber Laser ON:4~30 V;
Fiber Laser OFF:-3~2 V;
Maximum modulation frequency:5 kHz.
Laser emission indicator, MOSFET D pole, S pole output;
electric current <1A,Vds<30V
Passive Signal
Laser emission warning light negative,electric current<100mA
The main power supply is energized to the negative of the warning lamp,electric current
<100 mA
The laser emission and the main power supply are energized to the positive pole of the
warning light,electric current<400mA
During REM mode, the remote main control board is powered on, 24V active contact
input, and external voltage or grounding is not allowed; When pin 8 and 9 are closed,
the main control board will be powered on.
The laser emission and the main power supply are energized to the positive pole of the
warning light,electric current<400mA.
Front panel emergency stop output 1, relay contact output, passive contact ,
electric current<100mA,voltage<30V;