User Guide of RFL-C3000XZ~RFL-C12000XZ
33
The communication sends EEC, or the host computer software clicks the button
The communication sends ELE, or the host computer software clicks the button
XP1-A1 is high level, XP1-A6 is low level or floating;
XP1-A1 is high level, XP1-A3 is high level;
XP1-A1 is high level, XP1-A8~A14 are low level or floating;
XP1-A1 is high level, XP1-A6 is high level
XP1-A1 is high level, XP1-A3 is low level or floating
XP1-A1 is high level, not all XP1-A8~A14 are low level;
Communication send EMON or the host computer software click the
“ON button to emitting the laser;
The communication sends "EMOFF" or the host computer software clicks the
“OFF” button to turn off the laser;
The communication sends ABN or the host computer software clicks the button to
output guide laser
Communication send ABF or the host computer software click the button to turn
off the guide laser
Communication sends SDC XX to set the power percentage, XX represents the power percentage,
or the host computer software clicks the button
5.1 ON Mode
InON mode, users can set different operating modes by using the Raycus Laser Control System
(RLCS) or using a direct communication command method, which can be memorized by the laser source
even after powering off.

Table of Contents