EasyManua.ls Logo

Raycus RFL-3000/3000-ABP - Page 74

Raycus RFL-3000/3000-ABP
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C3000XZ~RFL-C12000XZ
70
4
Wait for sync
signal dropping
Null
5
Wait
065000ms (int)
5
GOTO
0
99
line
-1
Switch at low
sync signal
Jump to different line when comply
0
99
line
-2
Switch at high
sync signal
Jump to different line when comply
0
99
line
01000000
Switch at waiting
time due
Jump to different line when comply
6
OUT
1
SO
1
sync signal low
level output
2
sync signal high
level output
7
EXT
Power
1
010V
2

Table of Contents