Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide
RFL-C2000S-HP /RFL-C3000S-HP /RFL-C4000S-HP/RFL-C6000S-HP
27
RPRR
Read Pulse Repetition Rate
Send
:
“RPRR\r”
Return:“RPRR:10\r”
(Pulse Repetition Rate 10Hz)
RBT
Read Board Temperature
Send:“RBT\r”
Return
:
“RBT
:
36.6\r”
RPW
Read Pulse Width
Send:“RPW\r”
Return
:
“RPW
:
5.5\r”
(Pulse Width is 5.5ms)
RCT
Read Laser Temperature
Send
:
“RCT\r”
Return:“RCT:34.5\r”
ROP
Read Output Power – Reads the output
power in watts.
Send:“ROP\r”
Return
:
“ROP
:
4000.4\r”
RSN
Read Serial Number – Reads the serial
number of the device.
Sent: “RSN”
Return: “RSN:221200251\r”
PERR
Reset Errors
–Clear internal errors
Send
:
“PERR\r”
Return:“PERR\r”
RIP
Read IP
– Read the current IP address
Send:“RIP\r”
Return
:
“RIP
:
192.168.0.10\r“
RMASK
Read Sub-net Mask
– Read the current sub-net mask address
Send:“RMASK\r”
Return
:
“RMASK
:
255.255.255.0\r”
SIP
Set IP
– Set LaserIP
Send
:
“SIP 192.168.0.10\r”
Return:“SIP:192.168.0.10\r”
SMASK
Set Sub-net Mask
– To set the sub-net mask, append a string
of decimal digits with "."
Send:“SMASK 255.255.255.0\r”
Return
:
“SMASK
:
255.255.255.0\r”
SIP
Set IP
– To set the IP address, you need to attach
a string of decimal digits with "."
Send
:
“SIP 10.0.0.231\r”
Return:“SIP:10.0.0.231\r”
SUT
Set Up Time
– Set power rise time (unit: ms)
Send
:
“SUT 50\r”
Return:“SUT:50\r”
SDT
Set Down Time
– Set power drop time (unit: ms)
Send:“SDT 50\r”
Return
:
“SDT
:
50\r”
RUT
Read Up Time
– Read power rise time (unit: ms)
Send:“RUT \r”
Return:“RUT:50\r”
RDT
Read Down Time
– Read power drop time (unit: ms)
Send
:
“RDT \r”
Return:“RDT:50\r”
PSRT
Program Start
Send:”PSRT 1\r”
Return
:
“PSRT
:
1\r
PSTP
Program Stop
Send:”PSTP\r”
Return:“PSTP\r