24
Positive edge activates
emission in REM mode
Return for pin
17/18/19/21/22/23/24
Rising edge reset (the
resettable alarm)
High= The main power
supply is started
Caution: Please check the control voltage level and ensure that the level is in
accordance with the requirements. Over voltage and voltage ripple may damage
the product.
The Service Security Interface is pin 1-4 and pin2-3, of CTRL-INTERFACE.If the pin 2-3
and pin 1-4 are disconnected, the laser will immediately stop emitting light, and the laser Ready
signal output will change to low level. Be sure to short-circuit pin 2-3 and pin 1-4 before using
the laser. If it is not short-circuited, the laser will display InterLock alarm after power-on.
Interlock interface must not be connected to active signal, otherwise it
will cause interface damage and laser alarm.
4.4.2 TCP/IP Interface Configuration
Thedefault IP address of this product is 192.168.0.10, only supporting UDP communication.
The laser listens for connection on port is 8098, and the command must be sent in a single data
string.
Table 8 Thepin definitions of Ethernet interface