1.Distributionpanel.
2.Monitor.
3.VoltageControlModule(requiredonlyforOpenArrayradar
scanners).
4.Radarscanner.
5.GPSreceiver.
6.DigitalSounderModule(DSM)sonar.
7.Negative(-VE)bar.
8.Circuitbreaker.
9.Fuses.
10.Positive(+VE)bar.
11.GPMprocessorunit.
Powerdistributionnotes
•Raymarinerecommendsthatyouhaveadedicateddistribution
panelforyourG-Seriessystem.
•AllGPMprocessorunitsmustbepoweredfromasinglebreaker
orswitch,withappropriatecircuitprotection.
•Allmonitorsandancillaryequipmentshouldwherepossiblebe
wiredtoindividualbreakers.
•Eachmonitorshouldhaveitsowndedicatedpowercable.
•Equipmentwhichissusceptibletonoise(suchasVHFradios)
shouldNOTbewiredtothesamedistributionpanelasthe
monitors.Ifindoubtthemonitors(oraffectedequipment)canbe
wireddirectlybacktothebattery/powersourceviaadedicated
breaker.Refertotheseparatemonitordocumentationformore
details.
Circuitprotection
RecommendedloadsandprotectionratingsforG-Seriesequipment.
GPM400processor
AllGPM400processorsmustbeswitchedviaasinglebreaker.
NumberofGPM
unitsSupplyvoltage
Thermalbreaker
(overall)
Fuse
(individual)
12volts10amps10amps 1
24volts
5amps5amps
12volts20amps10amps 2
24volts10amps
5amps
12volts25amps10amps 3
24volts15amps
5amps
12volts35amps10amps 4
24volts20amps
5amps
Monitors
Supplyvoltage
Typicalisolator
switchThermalbreakerFuse
12volts15amps8amps12amps
24volts8amps4amps6amps
GVM400videomodule
SupplyvoltageThermalbreakerFuse
12volts1.2amps2amps
24volts1amp1amp
46G-Seriesinstallationinstructions