Loading...
YouMUSTtasuitablyratedfuseorbreaker
betweentheredwireandthebattery’spositive
terminal.
Refertotheinlinefuseratingsprovidedinthe
product’sdocumentation.
Ifyouneedtoextendthelengthofthepower
cable,ensureyouusesuitablyratedcableand
thatsufcientpower(12Vdc)isavailableatthe
SeaTalkng®backbone’spowerconnection.
A
BatteryconnectionscenarioA:suitableforavesselwith
acommonRFgroundpoint.Inthisscenario,ifyour
product’spowercableissuppliedwithaseparatedrain
wirethenitshouldbeconnectedtothevessel’scommon
groundpoint.
B
BatteryconnectionscenarioB:suitableforavessel
withoutacommongroundingpoint.Inthiscase,ifyour
product’spowercableissuppliedwithaseparatedrain
wirethenitshouldbeconnecteddirectlytothebattery’s
negativeterminal.
Implementationconnectiontodistribution
panel
Alternatively,theSeaT alkng®powercablemaybe
connectedtoasuitablebreakerorswitchonthe
vessel'sdistributionpanelorfactory-ttedpower
distributionpoint.
Thedistributionpointshouldbefedfrom
thevessel’sprimarypowersourceby8AWG
(8.36mm
2
)cable.
Ideally,allequipmentshouldbewiredtoindividual
suitably-ratedthermalbreakersorfuses,with
appropriatecircuitprotection.Wherethisisnot
possibleandmorethan1itemofequipment
sharesabreaker,useindividualin-linefuses
foreachpowercircuittoprovidethenecessary
protection.
Inallcases,observetherecommended
breaker/fuseratingsprovidedintheproduct’s
documentation.
Ifyouneedtoextendthelengthofthepower
cable,ensureyouusesuitablyratedcableand
thatsufcientpower(12Vdc)isavailableatthe
SeaTalkng®backbone’spowerconnection.
Important:Beawarethatthesuitablefuserating
forthethermalbreakerorfuseisdependentonthe
numberofdevicesyouareconnecting.
Moreinformation
Raymarinerecommendsthatbestpracticeis
observedinallvesselelectricalinstallations,as
detailedinthefollowingstandards:
BMEACodeofPracticeforElectricaland
ElectronicInstallationsinBoats
NMEA0400InstallationStandard
ABYCE-11AC&DCElectricalSystemsonBoats
ABYCA-31BatterychargersandInverters
ABYCTE-4LightningProtection
Sharingabreaker
Wheremorethan1pieceofequipmentsharesa
breakeryoumustprovideprotectionfortheindividual
circuits.E.g.byconnectinganin-linefuseforeach
powercircuit.
1
Positive(+)bar
2
Negative(-)bar
3
Circuitbreaker
4Fuse
Wherepossible,connectindividualitemsof
equipmenttoindividualcircuitbreakers.Wherethis
isnotpossible,useindividualin-linefusestoprovide
thenecessaryprotection.
Warning:Productgrounding
Beforeapplyingpowertothisproduct,
ensureithasbeencorrectlygrounded,in
accordancewiththeinstructionsprovided.
28