EasyManua.ls Logo

Raymarine i70 - Calibrating Water Temperature; Wind Calibration; Calibrating Wind; Aligning the Wind Transducer

Raymarine i70
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CalibratingWaterTemperature
TheWaterT emperaturereadingcanbecalibrated
asfollows:
Youwillneedansuitablethermometertomeasure
theWaterTemperature.
Fromafavoritepage:
1.SelectMenu.
2.SelectSet-up.
3.SelectTransducersSet-up.
4.SelectContinue.
Theinstrumentdisplaywillsearchforanddisplay
alistofconnecteddevices.(i.e.iTC-5,DSTor
transducerpod)
5.Selectthedevicethatthetransducer(s)youare
calibratingareconnectedto.
Alistofavailabletransducerdataisdisplayed,
6.*SelectSpeed.
Important:*SteponlyapplicabletoiTC-5.
7.SelectCurrentTemperatureoption.
8.Useasuitablethermometertomeasurethe
actualwatertemperature.
9.UsetheUpandDownbuttonstomatchthe
displayedWaterT emperaturetotheactualWater
Temperaturemeasuredbythethermometer.
10.SelectSavetosavethesetting.
7.4Windcalibration
Calibratingwind
Youwillneedtobeunderway,withsufcientspace
toturninalargeslowcircleunhindered.
Conditionsshouldbecalm(i.e.aslightsea)and
asteadybreeze.Trytoensurethevesselisnot
rollingorpitchingtoomuch.
Fromafavoritepage:
1.SelectMenu.
2.SelectSet-up.
3.SelectTransducersSet-up.
4.SelectContinue.
Theinstrumentdisplaywillsearchforanddisplay
alistofconnecteddevices.(i.e.iTC-5,DSTor
transducerpod)
5.Selectthedevicethatthetransducer(s)youare
calibratingareconnectedto.
Alistofavailabletransducerdataisdisplayed,
6.*SelectWind.
Important:*SteponlyapplicabletoiTC-5.
7.SelectCalibrateWindXdcr.
8.Keepthevesselspeedbelow2ktsandobserving
thescreen,starttoturnthevesselinacircle,
thenselectStart.
9.Continueturningthevesselincirclesuntil
Completeisdisplayedon-screen.
Ifyourrateofturnistoofastduringcalibration,
aSlowDownmessageisdisplayed.Ifthis
happens,reduceyourrateofturnthiscanbe
achievedbyslowingdownand/orsteeringin
awidercircle.
10.SelectContinue.
11.IfrequiredusetheUPandDOWNbuttonsto
manuallyadjustthevaneoffset.
12.PressSELECTtocompletethecalibration
processandsavethesettings.
Ifrequiredyoucanmanuallyadjusteachpartofthe
calibrationstepsbyselectingtherelevantoptions
fromtheWindmenu.
Aligningthewindtransducer
Youwillneedtobeunderway,withsufcientspace
toturninalargeslowcircleunhindered.
48