Loading...
1.Selectthedevicethatthetransducer(s)youare
calibratingareconnectedto.
Alistofavailabletransducerdataisdisplayed,
2.*SelectSpeed.
Important:*SteponlyapplicabletoiTC-5.
3.SelectSpeedCalibration.
4.SelectAdvanced.
5.SelectAdjustCalibration.
6.SelectStart.
ThecurrentCalibrationTableisdisplayed.
7.SelecttherelevantCalibrationPointfromthe
table.
8.SelectOptions.
9.SelectAddcalpoint.
10.UsetheUpandDownbuttonstoadjustthe
displayedLogSpeedtomatchSOG,ifavailable
ortomatchyourestimatedactualspeed.
11.SelectAdd.
12.SelectOk.
13.Repeatsteps7to11foreachCalibrationPoint
youwanttoadd.
ThemoreCalibrationPointsthehigherthe
accuracyofLogSpeed.
Note:Ifthetextappearsredthenthenewreading
deviatestoofarfromthestoredreading.Youwill
needtoaddaCalibrationPointclosertothestored
readingatryagain.
EditingaCalibrationPoint
ExistingCalibrationPointscanbemanuallyedited.
FromtheAdvancedMenu:
1.SelectAdjustcaltable.
2.SelectStart.
3.HighlighttherelevantCalibrationPointfromthe
table.
4.SelectOptions.
5.SelectEditcalpoint.
TheCalibrationPointAdjustmentpageis
displayed.
6.UsetheUpandDownbuttonstoadjustthe
CalibrationFactorfortheselectedspeedto
matchyournewCalibrationFactor.
7.SelectDonetoreturntotheCalibrationTable.
8.Repeatsteps4to7forallCalibrationPointsthat
requireadjustment.
9.SelectFinishwhenalloftherequiredCalibration
Pointshavebeenadjusted.
DeletingaCalibrationPoint
CalibrationPointscanbedeletedfromtheCalibration
Table.
FromtheAdjustcaltablemenu:
1.SelectStart.
2.HighlighttheCalibrationPointyouwanttodelete.
3.SelectOptions.
4.SelectYestodelete.
TheCalibrationPointisdeletedfromthe
CalibrationTable.
ResettingtheCalibrationTable
TheCalibrationTablecanberesettofactorydefault
valuesbyfollowingthestepsbelow:
FromtheAdvancedMenu:
1.SelectResettodefaults.
2.SelectYes.
3.SelectOk.
TheCalibrationTableisresettofactorydefault
values.
EnteringanewCalibrationTable
AnewCalibrationTablecanbeaddedmanually.The
newCalibrationT ablereplacestheexistingtable
whichisdeleted.Thisisusefulwhenyouhavebeen
providedaspeciccalibrationtableforyourhulltype.
Note:YouwillneedtoworkoutyourCalibration
FactorsforeachCalibrationPointbeforeyoucan
createthenewCalibrationT able.
FromtheAdvancedMenu:
1.SelectEnternewcaltable.
2.SelectStart.
AllexistingCalibrationPointsaredeletedandyou
willbepromptedtoenternewCalibrationPoints.
3.UsetheUpandDownbuttonstoselectthe
desiredspeedthatyouwanttoaddaCalibration
Pointfor.
4.SelectNext.
5.UsetheUpandDownbuttonstoadjustthe
CalibrationFactortothecorrectvalue.
6.SelectDone.
7.SelectAddtoaddthenextCalibrationPoint.
8.Repeatsteps3to7forallCalibrationPointsyou
wanttoadd.
9.SelectFinishwhenallCalibrationPointshave
beenadded.
10.SelectOK.
Transducercalibration