EasyManua.ls Logo

Raymarine RAY90 - Power Up Troubleshooting

Raymarine RAY90
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.4Poweruptroubleshooting
Problemsatpowerupandtheirpossiblecausesandsolutionsaredescribedhere.
Productdoesnotturnonorkeepsturningoff
PossiblecausesPossiblesolutions
Blownfuse/trippedbreaker
1.Checkconditionofrelevantfusesandbreakersand
connections,replaceifnecessary(RefertoChapter13
Technicalspecificationforfuseratings.)
2.Iffusekeepsblowingcheckforcabledamage,broken
connectorpinsorincorrectwiring.
Poor/damaged/insecure
powersupplycable/
connections
1.Checkthatthepowercableconnectorisfullyinsertedinto
theunitandlockedinposition.
2.Checkthepowersupplycableandconnectorsforsignsof
damageorcorrosion,replaceifnecessary.
3.Withtheunitturnedon,tryflexingthepowercablenear
tothedisplayconnectortoseeifthiscausestheunitto
re-boot/loosepower,replaceifnecessary.
4.Checkthevessel’sbatteryvoltage,theconditionofthe
batteryterminalsandpowersupplycables,ensuring
connectionsaresecure,cleanandfreefromcorrosion,
replaceifnecessary.
5.Withtheproductunderload,usingamulti-meter,checkfor
highvoltagedropacrossallconnectors/fusesetc,replace
ifnecessary.
IncorrectpowerconnectionThepowersupplymaybewiredincorrectly,ensurethe
installationinstructionshavebeenfollowed.(RefertoChapter4
Cablesandconnectionsforcableandconnectionrequirements.)
Powersourceinsufficient
Withtheproductunderload,usingamulti-meter,checkthe
powersupplyvoltageasclosetotheunitaspossibletoestablish
actualvoltagewhenthecurrentisflowing.(RefertoChapter13
Technicalspecificationforpowersupplyrequirements.)
Productwillnotbootup(re-bootloop)
PossiblecausesPossiblesolutions
Powersupplyandconnection
Seepossiblesolutionsfrom‘Productsdoesnotturnonorkeeps
turningoffabove.
SoftwarecorruptionIntheunlikelyeventthattheproductssoftwarehasbecome
corruptedpleasetryre-flashingthelatestsoftwarefromthe
Raymarinewebsite.
Productdoesnotturnonorkeepsturningoff
PossiblecausesPossiblesolutions
Blownfuse/trippedbreaker
1.Checkconditionofrelevantfusesandbreakersand
connections,replaceifnecessary(RefertoChapter13
Technicalspecificationforfuseratings.)
2.Iffusekeepsblowingcheckforcabledamage,broken
connectorpinsorincorrectwiring.
Poor/damaged/insecure
powersupplycable/
connections
1.Checkthatthepowercableconnectorisfullyinsertedinto
theunitandlockedinposition.
2.Checkthepowersupplycableandconnectorsforsignsof
damageorcorrosion,replaceifnecessary.
Troubleshooting
141

Table of Contents