18
2450-4450
DÉRIV. PRIMAIRE DÉRIV. PRIMAIRE DÉRIV. PRIMAIRE
DÉRIV. PRIMAIRE DÉRIV. PRIMAIRE DÉRIV. PRIMAIRE
20 GPM 1-1/2" 1-1/2" 20 GPM 1-1/2" 1-1/2" 20 GPM 1-1/2" 2"
30 1-1/2" 1-1/2" 30 1-1/2" 2-1/2" 30 1-1/2" 3"
40 1-1/2" 2" 40 1-1/2" 3
*Sizing based on10 ft/sec flow rates
DIA. MIN. TUYAUX
2 UNITÉS 3-4 UNITÉS 5-6 UNITÉS
5450-8450
30 GPM
40
60
80
2"
2"
2"
2"
2"
3"
3"
4"
30 GPM
40
60
80
2"
2"
2"
2"
2-1/2"
3"
4"
4"
30 GPM
40
60
80
2"
2"
2"
2"
4"
4"
5"
5"
DIA. MIN. TUYAUX
2 UNITÉS 3-4 UNITÉS 5-6 UNITÉS
40 1-1/2" 4"
DÉBIT MIN. DE LA BOUCLE SECONDAIRE (SYSTÈME) = 120% DU DÉBIT REQUIS PAR L’APPAREIL DE CHAUFFAGE.
SCHÉMA DE TUYAUTERIE RECOMMANDÉ PAR RAYPAK; IL N’EST PAS DESTINÉ À
REMPLACER UN SYSTÈME CONÇU PAR UN INGÉNIEUR.
DE PISCINE
POMPE
DE PISCINE
12” MAX.
OU MIN.
POSSIBLE
THERMOPOMPE
THERMOPOMPE
THERMOPOMPE
3-4 APPAREILS
VOIR TABLEAU ”DIA. MIN. TUYAUX”
5-6 APPAREILS
VOIR TABLEAU ”DIA. MIN. TUYAUX”
THERMOPOMPE
THERMOPOMPE
THERMOPOMPE
PRODUITS
CHIMIQUES ICI
BOUCLE
PRIMAIRE
CLAPET ANTI-RETOUR N/F PAR GRAVITÉ, AU NIVEAU.
DIA. MIN. DES CONDUITES: AU MOINS CELUI DES
RACCORDS D’ENTRÉE/SORTIE DE L’APPAREIL. VOIR
TABLEAU ”DIA. MIN. TUYAUX” CI-DESSUS.
MODÈLES ILLUSTRÉS À
TITRE INDICATIF. LA
CONFIGURATION PEUT
VARIER EN FONCTIONS
DE LA CAPACITÉ DES
APPAREILS UTILISÉS.
PROLONGER DE 12” DE L’ENTRÉE DU
CHAUFFE-PISCINE POUR L’ÉQUILIBRAGE
HYDRAULIQUE.
VERS PISCINE
"B": VANNES D’ÉQUILIBRAGE
“C”: VANNES D’ISOLATION
FILTRE DE
PISCINE
TUYAUTERIE PRINCIPALE
TUYAUTERIE SECONDAIRE
TUYAUTERIE PRINCIPALE ET
SECONDAIRE POUR
INSTALLATIONS FUTURES.
LÉGENDE
SOUPAPE DE
SURPRESSION
POMPE
RACCORD-UNION
CLAPET DE
NON-RETOUR
ROBINET
SPHÉRIQUE
THERMOMÈTRE
Figure 11. Schéma de plomberie multi-appareils, boucle primaire/secondaire