40 8540573 • 16/09/2016 • Rev.20
JLR SERIES Resolution 40 mm
604
904
1204
Number of beams
30
45
60
Response time ms
17
23
28,5
Overall barrier ht. mm
736
1036
1336
PFHd *
1,02E-08
1,17E-08
1,32E-08
DCavg
#
98,37%
98,49%
98,57%
MTTFd
#
years
100
CCF
#
80%
JLR SERIES
Number of beams of light curtains
for detection of body in access control
2 3 4
Operating range Low / High
m
8 ÷ 30 / 18 ÷ 60
JLR (M12 connector) Multibeam SERIES
2B
3B
4B
Number of beams
2
3
4
Distance between beams mm
500
400
300
Response time ms
7
7
7
Overall barrier ht. mm
736
1036
1136
PFHd *
7,53E-09
7,70E-09
7,87E-09
DCavg
#
97,94%
97,99%
98,03%
MTTFd
#
years
100
CCF
#
80%
* IEC 61508
#