Commissioning
Vacuum spray degassing06.07.2016 - Rev. B English
7.5
Starting Automatic mode
Automatic mode can be started as soon as the system is filled with water and the gases contained have been vented.
Press "Auto" on the controller's operator panel.
During commissioning, continuous degassing is automatically activated to remove any residual free or dissolved gases from the system.
This time can be set in the Customer menu as required by the system conditions. The default setting is 24 hours. Subsequent to the
continuous degassing, the device automatically switches to interval degassing.
Note!
The commissioning process is now concluded.
Notice!
The "ST" dirt trap in the "DC" degassing line must be cleaned after the expiry of the continuous degassing time at the
latest,
see chapter 10.2.1 "Cleaning the dirt trap" on page 49 .