8 REFUsol 40K / 46K-MV REFU Elektronik GmbH
2
Safety Information
Pos: 10 /Inverter M anuals/Sic herheitshinweise/ Bestimmun gsgemäße V erwendung/8 40 842 @ 1\mo d_14048120 09063_641.d ocx @ 6913 @ 2 @ 1
2.1
Designated Use
The REFUsol 40K / 46K-MV inverter, also referred to in these operating instructions as the inverter, is a
solar inverter, which transforms the direct current generated by the PV generator (photovoltaic modules)
into alternating current and feeds this into the power supply network.
The 40K is connected as a transformerless inverter directly to the low voltage supply network.
The connection of the 46K-MV is connected via an isolating transformer to the medium-voltage supply
network.
The inverter has been constructed according to the current state of technology and in line with the rules of
technical safety.
Both inverters meet the requirements of degree of protection IP65 and can be used indoors and outdoors.
An agreement of the network operator for connection and operation of the inverter for low voltage network
or medium voltage network must be present.
The technical design of the network connection, the required additional electrical equipment and to the
applicable connection and installation conditions should be clarified in this regard in advance.
Any other use is not considered to be a designated use. The manufacturer accepts no liability for any damage
resulting from this.
Pos: 12 /Inverter M anuals/Sic herheitshinweise/ Qualifikation des Person als/WR @ 1\m od_14047412 89759_641.d ocx @ 6754 @ 2 @ 1
2.2
Qualification of Personnel
Target group for these instructions are professionals who can assess the assigned tasks due to their
professional training, knowledge and experience as well as knowledge of the relevant provisions and
recognize possible dangers.
Electrical work must only be carried out by qualified electricians.
Only suitably trained and qualified personnel are allowed to work on this inverter. Personnel are regarded as
being qualified if they are sufficiently familiar with the assembly, installation, and operation of the product as
well as with all warnings and safety measures set out in these operating instructions.
Pos: 13 /Inverter M anuals/Sic herheitshinweise/ Gefahren du rch falsc hen Gebrauch/ 840 842 @ 1\ mod_1404825 753362_641. docx @ 6927 @ 2 @ 1