13
Systems
MAIN BREAKERBATTERY PANEL
As part of the
battery circuit
protection from
the battery to
the battery man-
agement system
and nally to
the dash panel
a breaker is in-
stalled within
40” of the bat-
tery. If the
breaker would
draw excessive
amperage it is
possible it could
“blow”. At this point it would need to be reset.
Always determine the reason why the breaker blew be-
fore resetting it.
To reset the breaker move the lever from the o po-
sition to the onposition. ese Buss brand breakers
are ignition protected which means they are sealed pro-
viding protection from spark sources. When replacing
breakers ensure they are marketed as being ignition
protected
POSSIBLE PROBLEMS/SOLUTIONS
1. It is possible that the battery manage-
ment system main circuit breaker may
trip from long-term arcing and heat.  e
breaker may need to be reset.
2. Breaker will not reset- Replace the
breaker. Contact the nearest Regal dealer for replace-
ment parts.
3. Breaker continues to “trip. Check the a ected equip-
ment to determine if it is responsible for the excessive
draw to trip the breaker. If the equipment is determined
to be within speci cations check for a short” in the wir-
ing circuit. Also, the breaker may be faulty. Contact the
nearest Regal dealer.