75
Systems
POSSIBLE PROBLEMS/SOLUTIONS-
FRESH WATER SYSTEM
1. Fresh water pressure pump cycles on
and off. Normally this type of action in-
dicates a water leak in the system. Check
all fresh water system related equipment
on the deck, cabin, and engine compart-
ment for leaks. Do not forget wash down
equipment including spigots. Look for puddled or drip-
ping water.
2. Using potable water system the water pressure is weak.
Check the fresh water pressure pump lter for debris.
Also, make sure the potable water tank level is suffi cient
at the monitor panel.
3. Water at sink or shower is hammering and has air bub-
bles in it. Check for air leaks in the system along with low
water levels in the potable water tank.
4. Water is backing up in the shower. Find the shower
sump pump. If it is full of water even when running there
normally is a clog at the pump screen. Clean as needed.
5. There is no water at any of the fresh water related equip-
ment such as faucets, showers and wash downs. Check to
make sure the fresh water pressure pump breaker is on.
Also, check the fresh water monitor for tank levels at the
salon monitor panel.
6. The water system has a bad odor. Use the fresh water
pressure pump to drain the fresh water system. Do not
drink the water as it may be contaminated. Sanitize the
water system as explained in Chapter 10.
7. There is no hot water. Turn the hot water heater break-
er to the off position. Remove the back cover on the wa-
ter heater and check the reset button. Push to reset. Also,
the heating element may of malfunctioned. At this point,
call a service technician.