79
Systems
Wall Control Panel Blue Backlighting Description:
The holding tank icon in the lower right hand corner
of the control panel is not lighted. Toilet system is off
or not receiving power.
The holding tank icon is normally green. This means
the holding tank is less than full.
The holding tank icon is red. The holding tank is full
or near full with the ush lockout (prevents Flush
operation when holding tank is full) activated.
Tank icon fl ashes
Sleep mode (non-use for 8 hours) causes the lights to
go out. Pushing the ll or ush button momentarily
will return lighting cycle.
Single Flush Override of Flush Lockout
1. If the holding tank is full the ush lockout cycle will
not allow the bowl to be ushed and the fl ush button will
be lighted red.
2. For emergency use only the ush button can be held for
8 seconds and a ush will occur. This can be accomplished
because the full sensor connected to the holding tank
is usually placed a bit below the actual full capacity of
the tank. Flushing more than 5 times using the override
feature may force waste into plumbing system. Regal is
not responsible for damage to equipment, or injury or
death due to overfl ow of waste due when ush lockout
is overridden. Again, refer to toilet vendor information
in the owner’s information packet.
CAUTION
!
POSSIBLE OVERFLOWING
OF THE WASTE HOLDING TANK
CAN OCCUR DUE TO USING
THE SINGLE FLUSH OVER-RIDE FUNCTION.
FOR EMERGENCY USE ONLY.
Typical Dockside Pump-Out
There is a tting located on the deck
labeled “waste.This tting is used
to pump out the waste tank. Nor-
mally a pump out station is found
at most marinas. After removing
the tting cover a special hose is inserted into the tting
and the machine then removes the waste. Normally there
is a charge for the service. Make sure they connect the
hose to the “waste” tting. Of course when cruising in
international waters the overboard discharge pump may
be used. See the section on using the macerator.
As stated earlier there is
a waste lter installed in
the vent line between the
waste tank and the port
thru-hull tting. The l-
ter’s purpose is to keep
objectionable odors to a minimum from the waste tank.
It is recommended that the lter be changed yearly. It can
be ordered from your Regal dealer or from marine supply
stores. The waste lter is mounted in the sump (engine
compartment) near the waste tank.
Typical In-Line Vent Filter