35
Cosmetic Care & Maintenance
Read and become familiar
with the generator owner’s
manual. It provides a variety
of operational, safety and
troubleshooting information.
The output voltage under
a full load can be easily
periodically checked by
observing the AC voltage meter found on the AC/DC
panel. The output voltage should be between 110 -120
volts AC (60 hertz-US), and 220- 240 volts AC at (50 hertz-
International). Voltages outside these specifi cations could
indicate a generator malfunction. Make sure all uid levels
are checked before starting the generator. The generator
seacock handle must be in-line with the seacock and the
sea water strainer must be free from debris.
The generator features an automatic shut down system of
sensors controlling high exhaust temperature, high water,
low oil pressure, and high RPM. If one of these sensors
engages, the generator will shut down. The source of the
problem then needs to be determined. Use the owner’s
manual troubleshooting section as a reference.
There is a fuel fi lter in the system that periodically needs
checking and cleaning. Refer to the owner’s manual.
Disconnect the battery cables before doing any generator
maintenance. Inspect and clean the ame arrestor/air
intake periodically by blowing off with compressed air.
Inspect all fuel system ttings for leakage periodically.
Be sure proper ventilation is present when servicing
the fuel system components. Inspect all water and heat
exchanger ttings periodically for leaks. Repair or replace
components as needed. Be sure the generator is completely
cold before performing any maintenance on the water
system due to possible hot water and or antifreeze lled
components. Be sure to catch and dispose of any antifreeze
coolant properly. Refer to the generator owner’s manual
regarding antifreeze recommendations for type and
mixture concentrations.
There is a zinc anode located in the raw water part of
the heat exchanger. Replace if 50% erroded. It is self
sacrifi cing thereby reducing the effects of electrolysis to
the generator water system.
Check the drive belt defl ection with the generator stopped.
At the longest span, push down at the center. You should
generate a movement of 3/8 to 1/2 inch. Refer to the
generator manual for more information.
When refilling the crankcase with oil follow the
specifi cations given in the owner’s manual. Dispose of
used oil in an environmentally friendly manner. Following
are selected detailed maintenance functions on the diesel
generator. Refer to the generator owner’s manual for more
information.
AVOID SERIOUS INJURY
FROM ROTATING PARTS!
OPERATE THE GENERATOR ONLY
WHEN ALL SCREENS, COVERS &
GUARDS ARE IN PLACE.
WARNING
!
AVOID SERIOUS INJURY FROM A HOT
GENERATOR AND EXHAUST SYSTEM.
DO NOT WORK ON GENERATOR
UNTIL THE UNIT COOLS.
WARNING
!
Note: Read and understand the following safety warnings
before performing any maintenance procedures.
AVOID SERIOUS INJURY FROM
ACCIDENTAL GENERATOR STARTING!
DISCONNECT THE BATTERY CABLES
BEFORE WORKING ON THE GENERATOR.
WARNING
!