EasyManua.ls Logo

Renesas RL78 - Page 38

Renesas RL78
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RL78/G11 UART Reception in STOP Mode Using Middle-speed On-chip Oscillator IAR
R01AN3634EJ0100 Rev.1.00 Page 38 of 85
Feb. 15, 2017
Bit 7 – 6
CIS
011
CIS
010
Selection of Tlmn pin input valid edge
0 0 Falling edge
0 1
Rising edge
1 0
Both edges (when low-level width is measured)
1 1
Both edges (when high-level width is measured)
Bit 3 – 1
MD
013
MD
012
MD
011
Channel n operation mode setting Corresponding function TCR count operation
0 0 0 Interval timer mode
Interval timer /
Square wave output / Divider
function / PWM output (master)
Counting down
0 1 0 Capture mode Input pulse interval measurement Counting up
0 1 1
Event counter mode
External event counter Counting down
1 0 0
One-count mode
Delay counter / One-shot pulse
output / PWM output (slave)
Counting down
1 1 0
Capture & one-count mode
Measurement of high-/low-level width
of input signal
Counting up
Other than
above
Setting prohibited
Bit 0
Operation mode
(Value set by the MDmn3 to MDmn1 bits
(see table above))
MD
010
Setting of count start and interrupt
Interval timer mode (0, 0, 0)
• Capture mode (0, 1, 0)
0
Timer interrupt is not generated when counting is started
(timer output does not change either).
1
Timer interrupt is generated when counting is started
(timer output also changes).
• Event counter mode (0, 1, 1)
0
Timer interrupt is not generated when counting is started
(timer output does not change either).
• One-count mode
Note2
(1, 0, 0)
0
Start trigger is invalid during counting operation.
At that time, interrupt is not generated.
1
Start trigger is valid during counting operation
Note 3.
At that time, interrupt is not generated.
• Capture and one-count mode (1, 1, 0)
0
Timer interrupt is not generated when counting is started
(timer output does not change either).
Start trigger is invalid during counting operation.
At that time, interrupt is not generated.

Related product manuals