EasyManua.ls Logo

Renesas RL78 - TAU0 Channel 3 Operation Stop Function

Renesas RL78
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RL78/G11 UART Reception in STOP Mode Using Middle-speed On-chip Oscillator IAR
R01AN3634EJ0100 Rev.1.00 Page 77 of 85
Feb. 15, 2017
5.9.17 TAU0 channel 3 operation stop function
Figure5.22 shows the flowchart for TAU0 channel 3 operation stop function.
Figure 5.22 TAU0 Channel 3 Operation Stop Function
Timer channel stop register 0 (TT0)
Set to TAU0 operation stop.
TAU0 Channel 3 O
p
eration Disable
Symbol: TT0
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0 0 0 0 TTH
03
0 TTH
01
0 0 0 0 0 TT0
3
TT0
2
TT0
1
TT0
0
x x x x x x x x x x x x 1 x x x
Bit 3
TT
03
Operation stop trigger for channel n
0 Clears TEmn bit to 0 and goes to count operation stop state.
1 Operation stopped (stop trigger generated)

Related product manuals