10. Commissioning
First insert batteries in the base station. Shortly after this (within 1 minute), insert the batteries in the out-
door sensor.
Proceed as follows:
• Open the battery compartment on the rear of the base station and insert three type AA/Mignon batteries with correct
polarity (observe plus/+ and minus/-).
• Close the battery compartment again.
Alternatively, the base station can also be operated via a suitable mains adapter (not enclosed, can be
ordered separately). The batteries then serve as back-up in case of power outage.
• Rightafterinsertingthebatteriesintothebasestation,alldisplaysegmentsappearbriey,thedisplaylightingis
switched on and a brief signal sound is emitted. The display lighting goes out again.
• Thedisplayshowstherstmeasuredvalues(indoortemperature,indoorhumidity,barometricpressure).
If only chaotic characters appear in the display, take out the batteries for a few seconds and insert them
again.
• The base station will now scan for the outdoor sensor signal for 3 minutes.
Important!
Do not move the base station and outdoor sensor and do not push any button. If you push a button at the
base station, scanning for the outdoor sensor is interrupted!
• Now insert the enclosed special rechargeable batteries into the battery compartment of the temperature/humidity
sensor in the right polarity. The LED lights up for 6 seconds and goes out again.
IftheLEDdoesnotlightup,checkitspolarity.Itisalsopossiblethattherechargeablebatteriesareat.In
this case, you need to charge them in full sunlight in the outdoor sensor for at least one day.
Ifthebasestationcannotndanyoutdoorsensorwithin240minutes,thesensorscanwillautomatically
restart.
• Theoutdoorsensorwilltransmittherstmeasureddatatothebasestation.Theseshouldnowbedisplayed(out-
door temperature, outdoor humidity, etc.).
• The outdoor sensor now scans for the DCF signal for a few minutes.
The DCF receiver is installed in the housing of the temperature/humidity sensor. This leads to much less
interference in DCF reception than in other weather stations.
Observe:
If you have not installed the outdoor sensor assembled in chapter 8 with the sensors in the outdoor area
yet, but it is still within a building, there may be reception problems (DCF time and date are not displayed
on the base station).
Werecommendthatyourstinstalltheoutdoorsensoroutdoorsandtheninserttheincludedbatteriesinto
the battery compartment of the temperature/humidity sensor. Alternatively, at least put the outdoor sensor
byawindoworonabalconyforthersttest.