EasyManua.ls Logo

Resol DL2 - 9.2 Log Interval Configuration; Log Mode Configuration

Resol DL2
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
InstallationData export / CongurationEliminating errors Conguration Web-Interface Indications
en
Port routing in the router
Note
Not all routers support port routing. For futher information consult the
router documentation.
In order to access, over the Internet, one or several Dataloggers connected to one
router, port routing has to be congured in the router.
The DL2 Datalogger communicates via the following ports:
Web interface port: 443 (adjustable, default port: 443)
RESOL RPT Parameterisation Tool/RESOL ServiceCenter port: 7053 (non-ad-
justable)
In order to carry out port routing in the router, proceed as follows:
1. Assign a static LAN IP address to the DL2 Datalogger using the conguration
menu of the router.
2. Assign a port to the IP address menu using the conguration menu of the
router.
In this example (see table below), 3 DL2 Dataloggers are assigned 1 Web interface
port and 1 RESOL ServiceCenter software port each.
See chap. 9.3 Logmodeconguration, page 19.
The Log interval determines the interval in which the DL2 Datalogger logs data.
Note
Log intervals between 1 second and 86400 seconds (24 hours) are pos-
sible.
Note
The smaller the log interval, the more memory capacity is used.
Example: Port routing
Datalogger
number
DynDNS address
Port routing
from port:
Port routing
to port:
DL2 LAN IP
1 www.Datalogger.ath.cx:443 443 443 192.168.0.10
2 www.Datalogger.ath.cx:444 444 443 192.168.0.11
3 www.Datalogger.ath.cx:445 445 443 192.168.0.12
1 www.Datalogger.ath.cx:7053 7053 7053 192.168.0.10
2 www.Datalogger.ath.cx:7054 7054 7053 192.168.0.11
3 www.Datalogger.ath.cx:7055 7055 7053 192.168.0.12
9.2 Logintervalconguration
In order to congure the log interval, proceed as follows:
1. In the main menu DeviceCong, select the submenu General.
2. On the LoggingConguration tab, in the Log interval input eld, enter
the desired value
3. Click Saveconguration.
The message Congurationsavedsuccessfully! appears.
Example: Memory capacity
Capacity: 160 MB
Log interval 1 DeltaSol
®
MX
1 DeltaSol
®
MX,
1 EM, 1 heating ciruit activated
1 DeltaSol
®
MX,
3 EM, 3 heating circuits
activated, 1 HQM activated
75 s 7 months 5 months 4 months
150 s
15 months 12 months 9 months
300 s
30 months 24 months 18 months
9.3 Logmodeconguration
The Log mode determines how the DL2 Datalogger behaves when its internal
memory capacity is fully used.
There are 2 different settings possible for the log mode conguration:
Cyclic logging (factory setting): When the memory capacity is fully used, the old-
est data are overwritten.
Linear logging: When the memory capacity is fully used, data logging stops.
In order to congure the log mode, proceed as follows:
1. In the main menu DeviceCong, select the submenu General.
2. On the Logging Conguration tab, in the Log mode dropdown menu,
select the desired value.
3. Click Saveconguration.
The message Congurationsavedsuccessfully! appears.

Table of Contents