3.3 VBus
®
/ data communication
Terminal connections of the Datalogger
The DL2 Datalogger is to be connected to the controller via the pre-connected
VBus
®
cable. The corresponding terminal allocation is described in the controller
manual.
The VBus
®
cable can be extended using the terminal block included and a common
two-wire cable.
The VBus
®
cable is pre-connected to the Datalogger terminals and . Another
module can be connected to the terminals and .
3.4 LAN Connection
The DL2 Datalogger can be connected to a computer or a router by using a net-
work cable (CAT5e, RJ45).
Î Connect the network cable included to the network adapter of the computer
or the router.
For the next step of commissioning, see chap. 8 Basicconguration, page 14.
4 Indications, operating controls and connections
The following elements are featured on / in the housing of the DL2 Datalogger:
Operating control LED / Reset button
Memory capacity and VBus
®
signal LEDs
LAN connector
SD memory card slot
Power supply connection (inside the housing)
VBus
®
connection (inside the housing)
Positions of the operating controls and connections