23
InstallationData export / CongurationEliminating errors Conguration Web-Interface Indications
en
11.2 Data export over Web interface
Note
The internal processor of the DL2 Datalogger needs up to 30 minutes
to convert logged data. If the data are required in a text format (tab sep-
arated, Windows), the data can also be exported onto a computer using
the VBus
®
protocol format. Then the data can be converted into a text
format (tab separated, Windows) more quickly.
For an overview of le formats available in the Web interface see chap. 16.1
Possibleexportleformats, page 26.
Note
Information about further processing transferred data are described in the
RESOL ServiceCenter software manual.
In order to copy logged data onto a computer, proceed as follows:
1. In the main menu Data, select the submenu Download.
2. In the File format dropdown menu, select the desired format.
3. Click the Start download button.
4. Save the le in a folder of choice.
12 FTPaccessconguration
The following requirements have to be met in order to upload or download data to
and from the DL2 Datalogger by means of an FTP client software:
The FTP password has to be known.
FTP access must be enabled.
In order to congure the FTP access, proceed as follows:
1. In the main menuConguration, select the submenu Network.
2. On the FTP conguration tab, in the FTP server enabled? input eld,
select Ye s .
3. Tick the Change FTP password? checkbox.
4. Enter the current password into the Current FTP password input eld.
Factory setting: ftp
5. Enter the new password into the New FTP password input eld.
6. Enter the new password into the Repeat new FTP password input eld.
7. Click Saveconguration.
The message Congurationsavedsuccessfully! appears.
10 Firmware update with SD card
New rmware versions extend the functional range and enhance the operation.
The current software can be downloaded from www.resol.de/rmware.
In order to run a rmware update over the SD memory card slot, proceed as
follows:
1. Download the rmware from the Internet (www.resol.de/rmware) and save
it to your PC.
2. Extract the le.
Among the extracted les there is a folder called SDCARD.
3. Insert an SD card formatted with the FAT32 format into the PC.
4. Copy the contents of the SDCARD folder onto the rst level of the SD card.
There should then be a folder structure called RESOL/DL2 on the SD card, con-
taining the rmware le.
5. Remove the SD card from the PC and insert it into the SD card slot of the DL2.
The rmware update is being run and the DL2 automatically reboots. This may take
a few minutes. The operating control LED starts ashing, lights up for a while and
then all LEDs go out.
6. Wait until the operating control LED is permanently green.
11 Data export
There are 2 different ways to export logged data from the DL2 Datalogger:
Export logged data onto an SD memory card. The data are stored as a VBus
®
format le and can be read out on a computer using the RESOL ServiceCenter
software.
Export logged data onto a computer over the Web interface. Different le
formats can be selected.
11.1 Data export over SD card
In order to copy data onto an SD card, proceed as follows:
Î Insert the SD card into the SD card slot
The operating control LED ashes (green):
The card has been recognised and data are being transferred.
The operating control LED is permanently green:
The transfer is completed. The card can be removed.