The data can be displayed as follows:
• In a schematic drawing of the system in which sensor data are assigned to the
components.
• In a tabular overview (factory setting).
In order to reduce the data trafc from the local network to the Internet, the
background drawing of the system can optionally be stored on an Internet server.
Requirementsforthedisplayoflivedatainaschematicdrawingofthe
system
The following requirements must be met in order to display live data (of a control-
ler connected) in a schematic drawing of the system:
• A schematic drawing of the system must be created using a drawing program
(e. g. Inkscape or Graphic Works).
• The schematic drawing must be supplied in one of the following formats: *.jpg,
*.gif, *.png, *.bmp, *.tif.
• The RESOL ServiceCenter software must be installed on the computer.
• The FTP access to the DL2 Datalogger must be enabled.
See chap. 12FTPaccessconguration, page 23.
The address and the port of the DL2 Datalogger must be on hand.
See chap. 9.2 Logintervalconguration, page 19.
Uploading a system drawing
In order to upload a system drawing into the Web interface of the DL2 Datalogger,
proceed as follows:
1. Start the RESOL ServiceCenter software.
2. In the main menu Window, select the submenu Show view Î VBus
®
logging.
3. Click the Designer tab.
4. Right-click the empty graphic (white square) and select Edit.
5. Select Use background image and click the [...] button to the right.
6. Select the drawing prepared as a background image and click Open.
7. Click OK.
8. Click Connect.
9. Select the DL2 Datalogger and enter the remote access password.
10. Right-click the system drawing and select Î Add VBus
®
eld.
9.4 Networkconguration
The network conguration determines where the DL2 Datalogger obtains its IP
information.
There are 2 different settings possible for the network conguration:
• Dynamic (DHCP): The IP information is automatically assigned to the DL2
Datalogger by the DHCP server.
• Static: The user manually assigns date and time information to the DL2 Datalogger.
Note
Consult the system administrator before changing the factory settings!
In order to congure the network conguration, proceed as follows:
1. In the main menu DeviceCong, select the submenu Network.
2. In the LANcongurationmodedropdown menu, select the desired value.
3. Click Saveconguration.
The message Congurationsavedsuccessfully! appears.
The menu item IP Recovery can be used to automatically retrieve a new IP ad-
dress for the DL2 in the case that the previous one is lost. In order to congure the
automatic IP address conguration, proceed as follows:
1. In the IP Recovery menu item, select Ye s .
2. Click Saveconguration.
The message Congurationsavedsuccessfully! appears.
3. Restart the Datalogger
9.5 Datadisplayconguration
Example of a live data display
The DL2 Datalogger displays live data of the controller connected. In the tabular
overview, the data are refreshed automatically every 10 seconds.