EasyManua.ls Logo

Resol DL2 - 1 Overview

Resol DL2
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
en
1 Overview
The DL2 Datalogger is the interface between a RESOL controller and the Internet
and additionally permits logging of system data. The DL2 enables the access to the
system data via www.VBus.net.
Dimensions and minimum distances
Technical data
Housing: plastic PC-ABS and PMMA
Protection type: IP 20 / EN 60529
Protection class: III
Ambient temperature: 0 40 °C
Maximum altitude: 2000 m above MSL
Dimensions: Ø 130 mm, depth 45 mm
Mounting: wall mounting
Display: bar LED for monitoring the memory capacity, 1 illuminated push button
for indication of the SD card status
Interfaces: RESOL VBus
®
for the connection to the controller, LAN, SD card slot
Power supply:
Mains adapter: 100 – 240 V~, 1A / 5 V
, 2.1 A (Level 6)
Datalogger: 5V ± 5 %, 350 mA
Electrical energy source: ES1 (EN 62368-1)
Electrical power source: PS1 (EN 62368-1)
Thermal energy source: TS1 (EN 62368-1)
Mechanical energy source: MS1 (EN 62368-1)
Memory: 160 MB internal memory, with a logging interval of 5 min. sufcient for:
18 months for a systems with one DeltaSol
®
MX, 3 EM, 3 heating circuits
and 1 HQM
24 months for a system with one DeltaSol
®
MX, 1 EM and 1 heating ciruit
30 months for a system with one DeltaSol
®
MX
Remote access to the system via the VBus.net visualisation portal
Comfortable system parameterisation via the RESOL RPT Parame-
terisation Tool
Internal memory for datalogging
Data transfer via SD card
Firmware updates via Internet or SD card
Suitable for all RESOL controllers with VBus
®
130
45
130
45
130
45
Use mains adapter in dry interior
rooms only.
Mains adapter protection class: II Coaxial connector polarity:
internal: plus
external: minus (GND)

Table of Contents