Fig. 32: Position of lubrication points
The drive of the vibratory disc mill has 6 lubrication points (PS) which must be lubricated
regularly after 150 hours of operation.
Use a natural coloured, lithium soap grease (graphite free) such as Shell Gadus S2 V220 2 or
BP Energrease LS-EP 2.
7.2 Maintenance
Risk of loss of life due to an electric shock
High voltage due to capacitor discharge
– Due to the capacitor discharge on the frequency converter, the device
conducts voltage for up to 3 minutes after the mains plug has been
removed.
– You could touch live contacts when the device is open. An electric
shock can cause serious injuries in the form of burns and cardiac
arrhythmia, respiratory failure or cardiac arrest.
• Wait 3 minutes after removing the power cable before opening the
device.