15
Press ENTER again to exit.
10 ERRORS
The controller continuously checks for errors during operation. E.g. the below screen shows that the ground
speed is too high. (operator is driving faster than the programmed maximum speed setting)
An audible alarm and error message will display on screen for 4 seconds when an error occurs, then it will go off
and could come back on 3 minutes later if the error is not resolved. Others more serious errors will stay on the
screen until the controller power is cycled or the error is resolved.
Error Messages Suggested Solution Cycle Power Needed?
BLAST2LONG Turn off blast No
OVERSPEED Slow down, reset max speed No
SPIN OUTPUT Check cables, replace coil Yes
CONV OUTPUT Check cables, replace coil Yes
NO CONVEYOR Check cable/sensor No, switches to open loop
COIL SHORT Check cables, replace coil Yes
0KMh 11:35:07
SPIN‒M SALT‒C
0% 0kg
LOW GATE: 05 HIGH
Warn: OVERSPEED
Please Slow Down Truck