Z-FOLDING UNIT B660
B064 Series/B140 Series/G126 1-80 SM
6. Attach the ground plate [A] ( x 2) to the finisher (or the cover interposer tray).
NOTE: This is the ground with the flat plate attached with 2 vertical screws.
7. Open the front door of the finisher.
8. Pull out the lock lever [B] of the finisher ( x 1).
-or-
If the cover interposer tray is installed, pull out the lock lever of the cover
interposer tray.
9. Dock the Z-folding unit to the finisher.
10. Fasten the screw [B] ( x 1).
11. Fasten screw [E] to front lock bracket [F].
12. Fasten the rear lock bracket [D] ( x 1).
B660I013.WMF
[A]
[B]
[C]
[D]
[E]
[F]